Articles in this section

How to replace Fluidmaster 300 cap assembly?

A brief guide on replacing a Fluidmaster 300 Fill Valve Repair Kit - Cap and Stem Sub Assembly (Part No. GENGR-024).

GENGR-024 FM300 Valve Repair Kit

  1. Close water supply to the fill valve.

  2. Actuate the float to depressurize the fill valve

  3. Twist the cap and float assembly ¼ turn CCW NOTE: Raise the float arm to aid in removing the cap and float assembly.
    KBA1554-img1

  4. Pull off the cap and float from the fill valve.
    KBA1554-img2

  5. Remove the new cap and float assembly from its carton.
    KBA1554-img3

  6. Remove plastic wrap from cap and make sure rubber seal and pin are intact
    KBA1554-img4

  7. Line cap over the fill valve tube and push onto fill tube. NOTE: Raise the float arm to aid in removing the cap and float assembly.
    KBA1554-img5

  8. Turn ¼ turn CW until it snaps into place.
    KBA1554-img6

  9. Lift float up to make sure it is there is no interference with its function with any other tank component.
    KBA1554-img7

  10. If the float interferes with any interior component, adjust the position of the fill valve utilizing appropriate steps based upon the installation.